8.14 Selecting physical units
8.14.1 Motor standard
Selection options and parameters involved
The converter represents the motor data corresponding to motor standard IEC or NEMA in
di󹪜erent system units: SI units or US units.
Table 8-43 Parameters involved when selecting the motor standard
Parame‐
ter
Designation Motor standard IEC/NEMA, p0100 =
0
1)
IEC motor
50 Hz, SI units
1
NEMA motor
60 Hz, US units
2
NEMA motor
60 Hz, SI units
r0206 Power Module rated power kW hp kW
p0219 Braking resistor braking power kW hp kW
p0307 Rated motor power kW hp kW
p0316 Motor torque constant Nm/A lbf ft/A Nm/A
r0333 Rated motor torque Nm lbf ft Nm
p0341 Motor moment of inertia kgm
2
lb ft
2
kgm
2
p0344 Motor weight kg Lb kg
r0394 Rated motor power kW hp kW
r1493 Total moment of inertia, scaled kgm
2
lb ft
2
kgm
2
1)
Factory setting
It is only possible to change the motor standard during quick commissioning.
8.14.2 Unit system
Some physical units depend on the system of units selected (SI or US), for example the power
[kW or hp] or the torque [Nm or lbf ft]. You can select in which system of units the converter
represents its physical values.
Options when selecting the system of units
The following options apply when selecting the system of units:
p0505 = 1: System of units SI (factory setting)
Torque [Nm], power [kW], temperature [°C or K]
p0505 = 2: Referred system of units/SI
Represented as [%]
Advanced commissioning
8.14 Selecting physical units
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL 237