11.Mount the Power Module.
9
5'<



12.Switch on the 24 V converter power supply voltage or the 400 V converter supply.
13.If the 󹪝rmware upgrade was successful, the converter LED RDY turns green after several
seconds.
You have successfully updated the converter's 󹪝rmware to a newer version.
When there is an upgrade, your settings will be stored in the converter.
10.4.2 Firmware downgrade
When downgrading 󹪝rmware you replace the converter's 󹪝rmware with an older version. Only
update the 󹪝rmware to an older level if, after replacing a converter, you require the same
󹪝rmware in all converters.
Requirements
Your converter's 󹪝rmware is at least version V4.7.
You have the memory card with the 󹪝rmware for that particular converter.
You have saved your settings onto a memory card, in an operator panel or on a PC.
Corrective maintenance
10.4 Firmware upgrade and downgrade
Distributed converter for SIMOGEAR geared motors
382 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL