9.4 Identication & maintenance data (I&M)
I&M data
The converter supports the following identication and maintenance (I&M) data.
I&M data Format Explanation Associated param‐
eters
Example for the
content
I&M0 u8[64] PROFIBUS
u8[54] PROFINET
Converter-specic data, read only - See below
I&M1 Visible String [32] Plant/system identier p8806[0 … 31] "ak12-ne.bo2=fu1"
Visible String [22] Location code p8806[32 … 53] "sc2+or45"
I&M2 Visible String [16] Date p8807[0 … 15] "2013-01-21 16:15"
I&M3 Visible String [54] Any comment p8808[0 … 53] -
I&M4 Octet String[54] Check signature to track changes for Safe‐
ty Integrated.
This value can be changed by the user.
The test signature is reset to the value
generated by the machine if p8805 = 0 is
used.
p8809[0 … 53] Values of r9781[0]
and r9782[0]
When requested, the converter transfers its I&M data to a higher-level control or to a PC/PG with
installed STEP 7 or TIA Portal.
I&M0
Designation Format Example for the con‐
tent
Valid for PROFI‐
NET
Valid for PROFI‐
BUS
Manufacturer-specic u8[10] 00 … 00 hex --- ✓
MANUFACTURER_ID u16 42d hex (=Siemens) ✓ ✓
ORDER_ID Visible String [20] "6SL3246-0BA22-1FA0" ✓ ✓
SERIAL_NUMBER Visible String [16] "T-R32015957" ✓ ✓
HARDWARE_REVISION u16 0001 hex ✓ ✓
SOFTWARE_REVISION char, u8[3] "V" 04.70.19 ✓ ✓
REVISION_COUNTER u16 0000 hex ✓ ✓
PROFILE_ID u16 3A00 hex ✓ ✓
PROFILE_SPECIFIC_TYPE u16 0000 hex ✓ ✓
IM_VERSION u8[2] 01.02 ✓ ✓
IM_SUPPORTED bit[16] 001E hex ✓ ✓
Alarms, faults and system messages
9.4 Identication & maintenance data (I&M)
Distributed converter for SIMOGEAR geared motors
350 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL