11.2 Performance ratings Power Module - PM240M
General performance ratings
Feature Specication
Line operating voltage &
power ranges
3 AC 380 V (- 10%) … 480 V (+ 10%)
High Overload: 0.37 kW … 4.0 kW (0.5 hp … 5.0 hp)
Input frequency 47 Hz … 63 Hz
Output frequency 0 Hz … 650 Hz
cos φ 0.95
Converter eciency 95% … 97%
Overload capability (HO) 2 x Nominal output current for 3 seconds followed by 1.5 x Nominal output
current for 57 seconds every 300 seconds (averages as 110%).
For 4 kW variant:
1.6 x Nominal output current for 3 seconds followed by 1.5 x Nominal output
current for 57 seconds every 300 seconds (averages as 110%).
Inrush current Less than rated input current
Pulse frequency 4 kHz (standard); 4 kHz … 16 kHz (in 2 kHz steps)
Electromagnetic compati‐
bility
Internal Class A lters according to EN 55011
Protection level IP65/IP66 (when Power Module and Control Unit is fully assembled).
Temperature range CU: -10 °C … +55 °C (14 °F … 131 °F) - High Overload (HO)
Storage temperature -40 °C … +70 °C (-40 °F … 158 °F)
Humidity < 95% RH - non-condensing
Operational altitude Up to 1000 m (3280 ft) above sea level without derating
Protection features Undervoltage, Overvoltage, Overload, Ground faults, Short circuit, Stall pre‐
vention, Motor blocking protection, Motor overtemperature, Power Module
overtemperature, Parameter interlock
Standards UL, cUL, CE, C-tick
CE mark Conformity with EC Low Voltage Directive 73/23/EEC and ltered versions
also Electromagnetic Compatibility Directive 89/336/EEC
EM Brake 180 V DC (400 V half-wave rectied) 1A maximum
Technical data
11.2 Performance ratings Power Module - PM240M
Distributed converter for SIMOGEAR geared motors
390 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL