Requirement
The following preconditions apply:
• The converter power supply has been switched on.
• The PC and converter are connected with one another via a USB cable or via the eldbus.
• The converter settings are not protected against copying.
Download with active know-how protection with copy protection (Page 375)
Function description
Procedure
1. Go online.
2. Select "Online & diagnostics".
3. Select "Back up/reset".
4. Set the number of your data backup. You can back up 99 dierent settings on the memory
card.
5. Start the data transfer.
6. Wait until Startdrive has signaled that the data transfer has been completed.
7. Go oine.
You have transferred your settings from a memory card to the converter.
❒
10.2.1.3 Download from IOP-2 operator panel
Overview
You can transfer the converter settings that are backed up on the IOP-2 operator panel back into
the converter.
Corrective maintenance
10.2 Downloading the converter settings
Distributed converter for SIMOGEAR geared motors
368 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL