EasyManua.ls Logo

Siemens SINAMICS G110M - Assignment Tables

Siemens SINAMICS G110M
428 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.7.3 Assignment tables
Fixed speeds - Single Slave
Table 8-33 Fixed speeds via the motor control bits
AS-i.DO3 AS-i.DO2 AS-i.DO1 AS-i.DO0 Response in the converter
0 0 0 0 OFF1
0 0 0 1 On + 󹪝xed speed 1 (factory setting: 1500 rpm)
0 0 1 0 On + 󹪝xed speed 2 (factory setting: -1500 rpm)
0 0 1 1 On + 󹪝xed speed 3 (factory setting: 300 rpm)
0 1 0 0 On + 󹪝xed speed 4 (factory setting: 450 rpm)
0 1 0 1 On + 󹪝xed speed 5 (factory setting: 600 rpm)
0 1 1 0 On + 󹪝xed speed 6 (factory setting: 750 rpm)
0 1 1 1 On + 󹪝xed speed 7 (factory setting: 900 rpm)
1 0 0 0 On + 󹪝xed speed 8 (factory setting: 1050 rpm)
1 0 0 1 On + 󹪝xed speed 9 (factory setting: 1200 rpm)
1 0 1 0 On + 󹪝xed speed 10 (factory setting: 1350 rpm)
1 0 1 1 On + 󹪝xed speed 11 (factory setting: 1500 rpm)
1 1 0 0 On + 󹪝xed speed 12 (factory setting: 1650 rpm)
1 1 0 1 On + 󹪝xed speed 13 (factory setting: 1800 rpm)
1 1 1 0 On + 󹪝xed speed 14 (factory setting: 1950 rpm)
1 1 1 1 Acknowledge fault or OFF2
Modi󹪝ed addressing - scaling factors
Table 8-34 Scaling of the speed setpoint via AS-i.P0 … AS-i.P3
AS-i.P3 AS-i.P2 AS-i.P1 AS-i.P0 Scaling factor Frequency (Hz)
1 1 1 1 1 50
1 1 1 0 0.9 45
1 1 0 1 0.8 40
1 1 0 0 0.7 35
1 0 1 1 0.6 30
1 0 1 0 0.5 25
1 0 0 1 0.45 22.5
1 0 0 0 0.4 20
0 1 1 1 0.35 17.5
0 1 1 0 0.3 15
0 1 0 1 0.25 12.5
0 1 0 0 0.2 10
0 0 1 1 0.15 7.5
0 0 1 0 0.1 5
Advanced commissioning
8.7 Control via AS-i
Distributed converter for SIMOGEAR geared motors
212 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL