EasyManuals Logo

Siemens SINAMICS G110M User Manual

Siemens SINAMICS G110M
428 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #402 background imageLoading...
Page #402 background image
A.1.3 Firmware version 4.7 SP9
Table A-3 New functions and function changes in 󹪝rmware 4.7 SP9
Function SINAMICS
G120 G120D
*0
*&
&83
&8%
&8(
&86
&8'
&8'
(7SUR)&
1 Support of PM240‑2 FSG Power Modules - - - - -
2 Support of PM240‑2 Power Modules in push-through technology, frame
sizes FSD … FSF, for the following voltages:
3 AC 200 V … 240 V
3 AC 380 V … 480 V
3 AC 500 V … 690 V
- - - - -
3 Shortened switch-on time for PM330 Power Modules - - - - - - - -
4 Expansion of the support for 1FP1 synchronous-reluctance motor with the
following converters:
SINAMICS G110M
SINAMICS G120D
SINAMICS G120 with CU240B‑2 or CU240E‑2 Control Unit
A PM240‑2 Power Module is required to operate a 1FP1 synchronous-reluc‐
tance motor with SINAMICS G120
- - - -
5 Support of 1FP3 synchronous-reluctance motors
A PM240‑2 Power Module is required to operate a 1FP3 synchronous-reluc‐
tance motor along with a selective release from SIEMENS
- - - - - - - -
6 Support of 1LE5 induction motors - - - -
7 The converter supports forming of the PM330 Power Module DC link capac‐
itors
- - - - - - - -
8 Setting option for two output reactors using parameter p0235 at the SI‐
NAMICS G120C and SINAMICS G120 with PM240-2 FSD FSF Power Module
- - - -
9 E󹪟ciency-optimized operation of induction motors
Improved method "E󹪟ciency optimization 2"
10 New setting option for the "Technology application" p0500 = 5 during quick
commissioning
11 Expansion of the available PROFIdrive telegrams in the SINAMICS G120C to
include telegram 350
- - - -
12 An SSI encoder can be parameterized as motor encoder - - - - - - -
13 Expansion of the "Basic positioner" function to include the feedback signal
from traversing blocks to the higher-level control system
- - - - - - -
14 Feedback signal supplemented to indicate that a memory card is not inser‐
ted in the converter:
Parameter r9401 as BiCo parameter for the optional feedback signal to
the higher-level control system.
New alarm A01101
Appendix
A.1 New and extended functions
Distributed converter for SIMOGEAR geared motors
400 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL

Table of Contents

Other manuals for Siemens SINAMICS G110M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G110M and is the answer not in the manual?

Siemens SINAMICS G110M Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G110M
CategoryMedia Converter
LanguageEnglish

Related product manuals