IND, bit 0 … 7 (page index): = 90 hex (o󹪜set 6000 corresponds to 90 hex)
Because you want to read the parameter value, words 3 and 4 in the parameter channel for
requesting the parameter value are irrelevant. They should be assigned a value of 0, for
example.
3DUDPHWHUFKDQQHO
3:(KLJKUGZRUG3:(ORZWKZRUG,1'QGZRUG
3DJHLQGH[3DUDPHWHUQXPEHU6XELQGH[3DUDPHWHUYDOXH
3.(VWZRUG
'ULYHREMHFW,QGH[$.


Figure 8-15 Telegram for a read request from p7841[2]
PNU (parameter number) and page index
Parameter number PNU Page index
0000 … 1999 0000 … 1999 0 hex
2000 … 3999 0000 … 1999 80 hex
6000 … 7999 0000 … 1999 90 hex
8000 … 9999 0000 … 1999 20 hex
10000 … 11999 0000 … 1999 A0 hex
20000 … 21999 0000 … 1999 50 hex
30000 … 31999 0000 … 1999 F0 hex
60000 … 61999 0000 … 1999 74 hex
Subindex
For indexed parameters, the parameter index is located in subindex as hexadecimal value.
PWE: Parameter value or connector
Parameter values or connectors can be located in the PWE.
Table 8-32 Parameter value or connector
PWE 1 PWE 2
Parameter value Bit 15 … 0 Bit 15 … 8 Bit 7 … 0
0 0 8-bit value
0 16-bit value
32-bit value
Connector Bit 15 … 0 Bit 15 … 10 Bit 9 … 0
Number of the connector 3F hex The index or bit 󹪝eld
number of the connec‐
tor
Advanced commissioning
8.6 Drive control via PROFIBUS or PROFINET
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL 201