The DIP switches allows specic functions of the converter to be set and are shown in the table
below.
Table 5-2 Function of the DIP switches
DIP switch Function
① Selects current or voltage input for the analog inputs.
Temperature sensor - sets the type of temperature sensor tted to the motor.
87 Hz characteristic - set "ON" to operate the motor with the 87 Hz characteristic.
Electromechanical (EM) brake - select on if an EM brake is tted.
Motor reverse
② Switching frequency - the user can select one of seven dierent switching frequencies.
Ramp-up and ramp-down timings - user can select from 0.1 seconds to 70 seconds
③ PROFIBUS address DIP-switch for use with the PROFIBUS and USS variant of the CU240M.
Examples of the DIP switches and their individual settings are illustrated in the gures below.