Requirement
The DC braking function is possible only for induction motors.
NOTICE
Motor overheating as a result of DC braking
The motor will overheat if you use DC braking too frequently or use it for too long. This may
damage the motor.
Monitor the motor temperature.
Allow the motor to adequately cool down between braking operations.
If necessary, select another motor braking method.
Function description
With DC braking, a constant braking current 󹪞ows through the motor. As long as the motor is
rotating, the DC current generates a braking torque.
The following con󹪝gurations are available for DC braking:
DC braking initiated by a control command
DC braking when falling below a starting speed
DC braking when the motor is switched o󹪜
Regardless of the con󹪝guration, you also can de󹪝ne the DC braking as a reaction to certain
converter faults.
WARNING
Unexpected motor acceleration
In the following con󹪝gurations, the converter can accelerate the motor to the set speed
without requiring a further ON command:
- DC braking initiated by a control command
- DC braking when falling below a starting speed
An unexpected acceleration of the motor can cause serious injury or material damage.
Consider the behavior of the drive in the higher-level controller.
Advanced commissioning
8.20 Electrically braking the motor
Distributed converter for SIMOGEAR geared motors
312 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL