Pt1000 sensor
Using a Pt1000 sensor, the converter monitors the motor temperature and the sensor itself for
wire breakage and/or short-circuit:
Temperature monitoring:
Using a Pt1000 sensor, the converter evaluates the motor temperature in the range from
-48 °C ... +248 °C.
Set the temperature for the alarm and fault thresholds with parameter p0604 or p0605.
Overtemperature alarm (A07910):
- motor temperature > p0604 and p0610 = 0
Overtemperature fault (F07011):
The converter responds with a fault in the following cases:
- motor temperature > p0605
- motor temperature > p0604 and p0610 > 0
Sensor monitoring (A07015 or F07016):
Wire-break:
The converter interprets a resistance > 2120 Ω as a wire-break and outputs the alarm
A07015. After 100 milliseconds, the converter changes to the fault state with F07016.
Short-circuit:
The converter interprets a resistance < 603 Ω as a short-circuit and outputs the alarm
A07015. After 100 milliseconds, the converter changes to the fault state with F07016.
Parameter
Parameter Description Factory setting
p0335[[M] Type of motor cooling 0
p0601[0…n] Motor temperature sensor type 0
p0604[0…n] Mot_temp_mod 2/sensor alarm threshold 130 °C
p0605[M] Mot_temp_mod 1/2/sensor threshold and temperature value 145 °C
p0610[M] Motor overtemperature response 12
p0640[D] Current limit 0 Arms
Additional information on the motor temperature monitoring can be found in function
diagram 8016 of the List Manual.
˽