Table 3-5 Description and location of interfaces
Ite
m
Description Ite
m
Description
1
Status LEDs
9
AS-i connection and Aux power
2
Optical I/O connection
10
Digital inputs 0 and 1
3
Potentiometer
11
Mains supply connection
4
Mini USB connection
12
Braking resistor & motor connection terminals
5
Card reader (on underside of Power Mod‐
ule)
13
Communications & Power Interface (CPI) inter‐
face ribbon cable
6
Digital outputs 0 and 1
14
Commissioning DIP switches 1 & 2
7
Analog inputs 0 and 1
15
EM brake & mains supply connection terminals
8
Digital inputs 2 and 3
16
Communications cable
Protection against unauthorized access via the USB interface
WARNING
Unsafe operating states resulting from manipulation of the converter software
Manipulation of the converter software can cause unsafe operating states in your system that
may lead to death, serious injury and property damage.
Secure the USB interface of the converter against unauthorized access, e.g. with a USB port
lock available on the market.
Description
3.3 General layout SINAMICS G110M system
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL 33