Explanation of the application example using the ON/OFF1 command
Parameter p0840[0] is the input of the "ON/OFF1" block of the converter. Parameter r20031 is
the output of the AND block. To interconnect ON/OFF1 with the output of the AND block, set
p0840 = 20031.
212))
S>@
S>@ 
S>@

U
$1'
Figure A-5 Interconnecting blocks by setting p0840[0] = 20031
Appendix
A.2 Interconnecting signals in the converter
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL 411