EMC Immunity
The SINAMICS G110M drives have been tested in accordance with the immunity requirements
of category C3 (industrial) environment:
Table A-12 EMC Immunity
EMC Phenomenon Standard Level Performance
Criterion
Electrostatic Discharge (ESD) EN 61000-4-2 4 kV Contact discharge A
8 kV Air discharge
Radio-frequency Electromagnet‐
ic Field
EN 61000-4-3 80 MHz … 1000 MHz
10 V/m
A
Amplitude modulated 80 % AM @ 1 kHz
Fast Transient Bursts EN 61000-4-4 2 kV @ 5 kHz A
Surge Voltage EN 61000-4-5 1 kV di󹪜erential (L-L) A
1.2/50 μs 2 kV common (L-E)
Conducted EN 61000-4-6 0.15 MHz … 80 MHz
10 V/rms
A
Radio-frequency Common Mode 80 % AM @ 1 kHz
Mains Interruptions & Voltage
Dips
EN 61000-4-11 95 % dip for 3 ms A
30 % dip for 10 ms C
60 % dip for 100 ms C
95 % dip for 5000 ms D
Voltage Distortion EN 61000-2-4 10 % THD A
Voltage Unbalance EN 61000-2-4 3 % Negative Phase Sequence A
Frequency Variation EN 61000-2-4 Nominal 50 Hz or 60 Hz (± 4 %) A
Commutation Notches EN 60146-1-1 Depth = 40 % A
Area = 250 % x degrees
Appendix
A.3 Electromagnetic Compatibility
Distributed converter for SIMOGEAR geared motors
414 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL