EasyManua.ls Logo

Siemens SINUMERIK 810D

Siemens SINUMERIK 810D
327 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Assi
g
nin
g
Parameters to the Control and the PLC Pro
g
ram
6
03.96
6.10 Linear motors (1FN1 and 1FN3 motors)
6-162
Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) 04.00 Edition
9. Traverse axis and perform function check
Does the axis traverse in the correct direction with a positive
velocity setpoint?
No Change MD 32100 (travel direction)
Is the traversed distance correct? (Input = 10 mm ––> distance = 10 mm)
10. Set and perform referencing/adjustment
Incremental measuring system:
Referencing (see Section 6.9.12)
Absolute measuring system:
Adjustment (see Section 6.9.6)
11. Set software limit switches (see Section 6.9.11 under subheading
Monitoring of positions via software limit switches)
12. Optimization of axis controller settings
Note:
The automatic controller setting run does not produce any useful results for
linear motors since the measuring system mounting has a significant effect
on the control characteristic.
Current and speed controllers (see Section 10)
Position controller (see Section 10)
04.00