11
03.96
11.7 Data backup with VALITEK streamer on the MMC101/102/103 (SW 5.3 and lower)
11-278
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
Valitek PST
2
System Verify Connection
Activity Repetitions Connection
Reading Status 500 0
Sending Test Data Blocks 500 0
Receiving Test Data Blocks 500 0
Selected Port : lpt1 Rom Version 85 Revision B <esc>–Abort
Test complete. The connection is functional. Press a key ...
7. You can now, for example, perform a full data backup. To do this, select
menu item 3, Backup System means hard disk C.
PLEASE SELECT:
1 Select VALITEK Streamer Type
2 Test Connection to Streamer
3 Backup System
4 Backup Userdata
5 Restore from Tape
6 Uninstall MMC102/103 (Delete Files)
7 Return to Main Menu
Your Choice [1,2,3,4,5,6,7]?
The following message appears on the screen:
*** Current Configuration: Valitek PST
2
–M1200 ***
Backing up Partition C: ....
Continue ?
Your Choice: [Y,N]?Y
Select Y to start data backup.
8. With key 4, Backup User Data, you can select data backup of user data, i.e.
the batch file C:\TOOLS\BACK_USR.BAT is executed. All the archive files
under C:\DH\ARC.DIR are backed up by default. If you want to back up any
other files, enter the relevant directories in the file
C:\TOOLS\ BACK_USR.BAT.
PLEASE SELECT:
1 Select VALITEK Streamer Type
2 Test Connection to Streamer
3 Backup System
4 Backup Userdata
5 Restore from Tape
6 Uninstall MMC102/103 (Delete Files)
7 Return to Main Menu
Your Choice [1,2,3,4,5,6,7]?4