Scale parameters and functions of the belt scale
8.10 DR 8 date and time
SIWAREX WP241
Manual, 04/2014, A5E33713528A
105
The weighing module has its own hardware clock. The current date and time are specified by
or read from data record DR 8. The clock is buffered with a capacitor and can continue
operating for up to approximately 70 hours without a supply voltage. If you are using the
Modbus protocol, data record DR 48 must be used for the date and time.
● Set the date and time
● Transfer the data record to the scale
Table 8- 8 Assignment of data record 8
Data record
Contains no. of data record USHORT 2 r 8 - - 1341
Data record length information
Application Information about which
application the DR belongs to
USHORT 2 r 104 - - 1343
Version identifier Information about current data
USHORT 2 r 1 1 65635 1344
Date and time SIMATIC DTL format DTL 12 rw DTL#1970
-01-01-
- - 1345