Scale parameters and functions of the belt scale
8.10 DR 8 date and time
SIWAREX WP241
Manual, 04/2014, A5E33713528A
105
8.10
DR 8 date and time
The weighing module has its own hardware clock. The current date and time are specified by
or read from data record DR 8. The clock is buffered with a capacitor and can continue
operating for up to approximately 70 hours without a supply voltage. If you are using the
Modbus protocol, data record DR 48 must be used for the date and time.
Procedure
Set the date and time
Transfer the data record to the scale
Table 8- 8 Assignment of data record 8
Variable
Note
Type
L
Rw
Default
Min.
Max.
Register
Data record
number
Contains no. of data record USHORT 2 r 8 - - 1341
Length
Data record length information
USHORT
2
r
20
-
-
1342
Application Information about which
application the DR belongs to
USHORT 2 r 104 - - 1343
Version identifier Information about current data
record version
USHORT 2 r 1 1 65635 1344
Date and time SIMATIC DTL format DTL 12 rw DTL#1970
-01-01-
00:00:00.0
- - 1345