Scale parameters and functions of the belt scale
8.4 Calibration procedure
SIWAREX WP241
82 Manual, 04/2014, A5E33713528A
Step 3 (only for systems without speed sensor)
Following successful zero and span calibrations, you can additionally record and store a
speed correction with loaded belt during operation (commands "Start speed measurement
"belt loaded"" (72) and "Stop speed measurement "belt loaded"" (73)). A coarse load
characteristic of the drive can be recorded in this manner. Import using the command "Apply
speed parameters "belt loaded"" (86).
8.4.3
Specification of known speed parameters
Calibration of the speed as described above is always recommended. This guarantees
maximum accuracy for the speed calculation and thus maximum accuracy of the complete
system.
If it is not possible to calculate the speed or pulse constant, you can also enter the data
manually.
When using a speed sensor at DI.0, you must enter the following parameters manually:
DR3 → design speed = maximum speed of belt
DR3 → belt revolution pulses = total belt length x pulse constant of sensor
When operating without a sensor, you must enter the following parameters manually:
DR3 → design speed = maximum speed of belt
With an external speed input via DR19, you must enter the following parameters
manually:
DR3 → design speed = maximum speed of belt

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP241 and is the answer not in the manual?

Siemens SIWAREX WP241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP241
CategoryAccessories
LanguageEnglish

Related product manuals