Scale parameters and functions of the belt scale
8.18 DR 18 Control digital output
SIWAREX WP241
Manual, 04/2014, A5E33713528A
117
DR 18 Control digital output
If a digital output is defined in data record DR 7 for control with data record DR 18 (see
Assignment digital output DQ 0, 1, 2, 3 (Page 100)), you can control this output with data
record DR 18. Transfer is always for all four digital outputs. Only outputs which are
configured for control by DR 18 (see DR 7 Process interfaces (Page 97)) are enabled or
disabled in accordance with the content of data record DR 18.
● Check or adapt the desired parameter settings of the digital outputs in data record 7
● Define the value for digital output DQ,0, 1, 2, 3
● Transfer the data record to the scale
Table 8- 16 Assignment of data record 18
Contains no. of data record
Data record length information
Application Information about which application
USHORT 2 r 104 - - 1598
Version identifier
Information about current data record
version
USHORT 2 r 1 1 65635 1599
Definition for digital
output DQ.0, 1, 2, 3
(Page 118)
Definition for digital output 0=1 ->
DQ0 output enabled
(only applies if output is assigned
BIT 0 rw 0 0 1 1600.16
Definition for digital output 1=1 ->
DQ1 output enabled
(only applies if output is assigned
BIT 0 rw 0 0 1 1600.15
Definition for digital output 2=1 ->
DQ2 output enabled
(only applies if output is assigned
BIT 0 rw 0 0 1 1600.14
Definition for digital output 3=1 ->
DQ3 output enabled
(only applies if output is assigned
BIT 0 rw 0 0 1 1600.13