Scale parameters and functions of the belt scale
8.3 DR 3 Belt scale parameters
SIWAREX WP241
74 Manual, 04/2014, A5E33713528A
8.3.4
Unit for flow rate
The following units can be selected for the material flow rate:
0 t/h (metric)
1 kg/h (metric)
2 T/h (imperial)
3 TL/h (imperial)
4 lbs/h (imperial)
Note
If the jumper is closed to protect data with verification capability,
the parameter can no longer
be changed.
8.3.5
Resolution of weight and belt load
The resolution for the weight measurement and the belt load per length unit can be defined
in accordance with the standard EN 45501 (1*10**k, 2*10**k, 5*10**k]; k: -3 … 2) from
0.0001 to 50.
Note
If the jumper is closed to protect data with verification capability, the parameter can no longer
be changed.
8.3.6
Resolution of flow rate
The resolution for the material flow rate and totalizers 2 to 6 can be defined in accordance
with the standard EN 45501 (1*10**k, 2*10**k, 5*10**k]; k: -3 … 2) from 0.0001 to 50.
Note
If the jumper is closed to protect data with verification capability, the parameter can no longer
be changed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP241 and is the answer not in the manual?

Siemens SIWAREX WP241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP241
CategoryAccessories
LanguageEnglish

Related product manuals