Scale parameters and functions of the belt scale
8.28 DR 48 Date and time 2
SIWAREX WP241
Manual, 04/2014, A5E33713528A
137
8.28
DR 48 Date and time 2
The SIWAREX module has its own hardware clock. You can set and read the current date
and time using data record DR 48. The clock is buffered with a capacitor and continues to
operate for up to approximately 70 hours without a supply voltage. If you are not using the
Modbus protocol, data record DR 8 is used for the date and time.
Procedure
Set the date and time
Transfer the data record to the SIWAREX module
Table 8- 26 Assignment of data record 48
Variable
Note
Type
L
Rw
Default
Min.
Max.
Register
Data record
number
Contains no. of data record USHORT 2 r 48 - - 6960
Length
Data record length information
USHORT
2
r
24
-
-
6961
Application Information about which application the
data record belongs to
USHORT 2 r 104 - - 6962
Version identifier Information about current data record
version
USHORT 2 r 1 1 65635 6963
Year
Year
USHORT
2
rw
2012
2012
2010
6964
Month
Month
USHORT
2
rw
1
1
12
6965
Day
Day in month
USHORT
2
rw
1
1
31
6966
Hour
Hour
USHORT
2
rw
0
0
23
6967
Minute
Minute
USHORT
2
rw
0
0
59
6968
Second
Second
USHORT
2
rw
0
0
59
6969
Millisecond
Millisecond
USHORT
2
rw
0
0
999
6970
Day of the week
Day of the week
USHORT
2
rw
1
1
7