Scale parameters and functions of the belt scale
8.28 DR 48 Date and time 2
SIWAREX WP241
Manual, 04/2014, A5E33713528A
137
The SIWAREX module has its own hardware clock. You can set and read the current date
and time using data record DR 48. The clock is buffered with a capacitor and continues to
operate for up to approximately 70 hours without a supply voltage. If you are not using the
Modbus protocol, data record DR 8 is used for the date and time.
● Set the date and time
● Transfer the data record to the SIWAREX module
Table 8- 26 Assignment of data record 48
Data record
Contains no. of data record USHORT 2 r 48 - - 6960
Data record length information
Application Information about which application the
USHORT 2 r 104 - - 6962
Version identifier Information about current data record
USHORT 2 r 1 1 65635 6963