EasyManuals Logo

Siemens SIWAREX WP241 User Manual

Siemens SIWAREX WP241
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
Scale parameters and functions of the belt scale
8.28 DR 48 Date and time 2
SIWAREX WP241
Manual, 04/2014, A5E33713528A
137
8.28
DR 48 Date and time 2
The SIWAREX module has its own hardware clock. You can set and read the current date
and time using data record DR 48. The clock is buffered with a capacitor and continues to
operate for up to approximately 70 hours without a supply voltage. If you are not using the
Modbus protocol, data record DR 8 is used for the date and time.
Procedure
Set the date and time
Transfer the data record to the SIWAREX module
Table 8- 26 Assignment of data record 48
Variable
Note
Type
L
Rw
Default
Min.
Max.
Register
Data record
number
Contains no. of data record USHORT 2 r 48 - - 6960
Length
Data record length information
USHORT
2
r
24
-
-
6961
Application Information about which application the
data record belongs to
USHORT 2 r 104 - - 6962
Version identifier Information about current data record
version
USHORT 2 r 1 1 65635 6963
Year
Year
USHORT
2
rw
2012
2012
2010
6964
Month
Month
USHORT
2
rw
1
1
12
6965
Day
Day in month
USHORT
2
rw
1
1
31
6966
Hour
Hour
USHORT
2
rw
0
0
23
6967
Minute
Minute
USHORT
2
rw
0
0
59
6968
Second
Second
USHORT
2
rw
0
0
59
6969
Millisecond
Millisecond
USHORT
2
rw
0
0
999
6970
Day of the week
Day of the week
USHORT
2
rw
1
1
7
6971

Table of Contents