Communication
11.2 Communication via Modbus
SIWAREX WP241
164 Manual, 04/2014, A5E33713528A
11.2.5
Reading registers
The method for reading registers depends on whether they belong to the writable data
records (DR 3 to DR 29) or can only be read as current values (DR 30 to DR 34).
If you wish to read the registers from the data records DR 3 to DR 29, you must first export
these as a complete data record to the internal output buffer.
All Modbus registers of the individual parameters can be found in chapter Scale
parameters and functions of the belt scale (Page 69).
Example
A parameter is to be read from data record 3 (DR 3).
First, write register CMD3_CODE with 2003 (2000 plus the number of the data record =
read data record).
Then write CMD3_TRIGGER with "1". The DR3 is then updated in the Modbus buffer
memory.
It is now possible to read one or more registers with the corresponding variable(s). The
data consistency of the registers read at this time is guaranteed.
You can find all further command numbers in chapter Command lists (Page 147).
Example
A current measured value is to be read out from DR 30.
⇒ The register can be directly requested because its contents are automatically refreshed in
the SIWAREX module at the specified measuring rate of 100 Hz and are always available
up-to-date.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP241 and is the answer not in the manual?

Siemens SIWAREX WP241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP241
CategoryAccessories
LanguageEnglish

Related product manuals