153
Communication
11
11.1
Integration in SIMATIC S7-1200
11.1.1
General information
A SIWAREX WP241 occupies 32 bytes each in the I/O areas of the CPU. The maximum
number of SIWAREX WP241 weighing modules is defined as follows:
S7-1212 CPU → up to two WP241 weighing modules
S7-1214 CPU → up to eight WP241 weighing modules
S7-1215 CPU → up to eight WP241 weighing modules
S7-1217 CPU → up to eight WP241 weighing modules
Additionally observe the memory requirements for the respective function block calls.
Table 11- 1 Memory requirements of the function block
FB with DS communication
(FB241 "WP241PR")
Read weight and status
YES
Send commands
YES
Send parameters
YES
Main memory requirements in CPU
16 000 byte + n x 2 020 byte
Load memory requirements in CPU
202 000 byte + n x 53 000 byte
n = number of WP241 modules
The function block described above including HMI configuring can be downloaded as a
predefined example project ("Ready-for-use") from the Siemens Customer Support.
The latest firmware version for the weighing module can also be downloaded from the
Customer Support.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP241 and is the answer not in the manual?

Siemens SIWAREX WP241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP241
CategoryAccessories
LanguageEnglish

Related product manuals