Scale parameters and functions of the belt scale
8.22 DR 30 Process state
SIWAREX WP241
Manual, 04/2014, A5E33713528A
125
The current material weight of the loaded belt resting on the scale. The output is made in the
selected weight unit from the belt load.
The current material weight of the loaded belt acting on one unit of the weigh length.
Current belt load in % of nominal belt load
The current material flow rate (belt load x speed).
The current material flow rate (belt load x speed) in % of the nominal flow rate.
The current speed used to calculate the material flow rate. The output is made as length per
second.
The current speed used to calculate the material flow rate. The output is made in % of the
maximum speed.
Current master totalizer (S1)
The total material flow is summed after the start-up and switching-off of service mode.
Resetting the total is only possible using the "Load factory settings" command.