Commissioning
7.6 Service with SIWATOOL software
SIWAREX WP241
62 Manual, 04/2014, A5E33713528A
For example, if data record 3 is to be sent, right-click on "Calibration parameter (DR3)". A
submenu is then opened with the option for sending the respective data record to the
weighing module or for reading it from the module. All data records can only be sent to or
read from the SIWAREX as complete packets. It is not possible to read or write individual
parameters within a data record. Therefore the complete data record must initially be
received for every change to parameters within it. The desired parameter can then be edited,
and the data record returned. If the data record is not received, the danger exists that
different offline parameters will be sent to the scale and overwrite previously active and
intentionally defined parameters.
Figure 7-17 Sending/receiving a data record with SIWATOOL V7
Offline parameter assignment
All scale parameters can be edited and saved without an electronic weighing system.
This reduces the setup time. You can thus prepare the parameters for several scales in your
office, and subsequently transfer them to the electronic weighing system during setup.
Data from one scale currently in operation can be exported and used to set up another scale.