EasyManuals Logo

Siemens SIWAREX WP241 User Manual

Siemens SIWAREX WP241
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
Scale parameters and functions of the belt scale
8.12 DR 10 load cell parameters
SIWAREX WP241
108 Manual, 04/2014, A5E33713528A
8.12.1
Number of load cells
The number of load cells is required for automatic calibration.
8.12.2
50/60 Hz toggling
To improve the suppression of faults caused by the supply network, you can specify the
network frequency for signal filtering.
8.12.3
Load cell characteristic value
The characteristic value of the load cell(s) is required to correctly interpret the output voltage
from the load cell. The exact value can be entered if the measurement log for the load cell is
available. The mean value of all characteristic values is used if there is more than one load
cell.
Example
Characteristic value = 2.018 mV/V
8.12.4
Rated load of a load cell
The rated load of a load cell is required for checking the maximum weighing range of the
scales. The rated load is entered in the specified units of weight.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP241 and is the answer not in the manual?

Siemens SIWAREX WP241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP241
CategoryAccessories
LanguageEnglish

Related product manuals