Scale parameters and functions of the belt scale
8.17 DR 17 Control analog output
SIWAREX WP241
116 Manual, 04/2014, A5E33713528A
DR 17 Control analog output
If data record DR 17 is configured as the source for the analog output (see Analog output
source (Page 102)), specifying a control output sends a corresponding output current at the
analog output.
● In data record DR 7, check that "Control by DR17" has been configured as the source for
the analog output
● Check the analog output configuration (see Analog output source (Page 102))
● Enter a value in data record DR 17
● Transfer the data record to the scale
Table 8- 15 Assignment of data record 17
Data record
Contains no. of data record USHORT 2 r 17 - - 1588
Data record length information
Application Information about which application
the data record belongs to
USHORT 2 r 104 - - 1590
Version
Information about current data record
USHORT 2 r 1 1 65635 1591
Analog output
specification
Value which is to be output (only
relevant if source is "External
specification", see DR 7)
FLOAT 4 rw 0 - - 1592
Analog output specification
The value to be entered must be between the start value (Page 102) and the end value
(Page 103) of the analog output.