EasyManuals Logo

Siemens SIWAREX WP241 User Manual

Siemens SIWAREX WP241
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
Scale parameters and functions of the belt scale
8.25 DR 33 Totalizers
SIWAREX WP241
134 Manual, 04/2014, A5E33713528A
8.25.1
Current master totalizer (S1)
This totalizer contains the total of conveyed material since commissioning of the scale. The
master totalizer can only be reset by loading the factory settings.
8.25.2
Current main totalizer (S2)
The totalizer contains the quantity of material transported since the last memory reset. The
operating total must be logged in the case of trade scales requiring verification (available
soon). You can reset the total using command 670.
8.25.3
Totalizer 3 (S3), totalizer 4 (S4), totalizer 5 (S5)
The totalizers respond like the main totalizer S2. In the case of trade scales requiring
verification, these totals can be reset without logging.
You can reset the totals individually to 0 using the following commands:
S3 using command 671
S4 using command 672
S5 using command 673
8.25.4
Totalizer 6 (S6)
A special property of totalizer 6 is that it remains active even following the command "Stop
totalizing (652)", and therefore indicates the total amount. You can therefore carry out
material tests or calibrate the scale, for example, without recording the "transported material"
(calibration weight, test chain) into the balance.
You can reset the total S6 using command 674.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP241 and is the answer not in the manual?

Siemens SIWAREX WP241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP241
CategoryAccessories
LanguageEnglish

Related product manuals