Scale parameters and functions of the belt scale
8.22 DR 30 Process state
SIWAREX WP241
122 Manual, 04/2014, A5E33713528A
8.22
DR 30 Process state
Current states and process values in the scales can be monitored using process values and
advanced process values from data record DR 31. Monitoring selected data during
commissioning is extremely useful as it helps you to optimize parameters.
Procedure
Read data record DR 30 cyclically or on a time-triggered basis
Display/analyze the required tags
It is not always necessary to cyclically read data record DR 30. The most important process
variables are already cyclically transferred via the SIMATIC I/O interface.
For Modbus communication with a Modbus master, data record DR 30 (a tag area is read)
must be polled for you to receive the current data on the status of the scale.
Table 8- 20 Assignment of data record 30
Variable
Note
Type
L
Rw
Default
Min.
Max.
Register
Data record number
Contains no. of data record
USHORT
2
r
30
-
-
3000
Length
Data record length information
USHORT
2
r
68
-
-
3001
Application Information about which application the
data record belongs to
USHORT 2 r 104 - - 3002
Version identifier Information about current data record
version
USHORT 2 r 1 1 255 3003
In zero offset range
Set if belt load within offset range
BIT
2
r
0
-
-
3004.16
Zero offset procedure
active
Set if automatic zeroing is switched on BIT 0 r 0 - - 3004.15
Zero tracking active Set if automatic zero tracking is switched
on
BIT 0 r 0 - - 3004.14
Min. belt load for
totalizing
Set if minimum belt load for totalizing
(DR6) is violated. Totalizing not carried
out if TRUE.
BIT 0 r 0 - - 3004.13
Max. material flow rate
exceeded
Set if maximum material flow rate is
exceeded
BIT 0 r 0 - - 3004.12
Min. load for totalizing
Set if minimum load is violated
BIT
0
r
0
-
-
3004.11
Min. belt speed
violated
Set if minimum belt speed is violated BIT 0 r 0 - - 3004.10
Max. belt speed
exceeded
Set if maximum belt speed is exceeded BIT 0 r 0 - - 3004.9
Min. belt load violated
Set if minimum belt load is violated
BIT
0
r
0
-
-
3004.8
Max. belt load
exceeded
Set if maximum belt load is exceeded BIT 0 r 0 - - 3004.7
Reserve
Not used
BIT
0
r
0
-
-
3004.6
Reserve
Not used
BIT
0
r
0
-
-
3004.5
Belt is running
Set if belt is running
0
r
0
3004.4
Totalizing active
Set if totalizing is running
BIT
0
r
0
3004.3
Totalizing enabled
Set if totalizing is enabled
BIT
0
r
0
3004.2