Scale parameters and functions of the belt scale
8.20 DR 20 Message configuration
SIWAREX WP241
120 Manual, 04/2014, A5E33713528A
8.20
DR 20 Message configuration
You can suppress technological messages in data record DR 20. If you set the value for an
individual message to "0", this message is no longer generated as if it did not exist. We
recommend that you do not suppress messages.
NOTICE
Suppressing a message
Suppressing messages could mean that a fault in the belt scale is not recognized.
Procedure
Define the value for a message to be suppressed to 0
Transfer the data record to the scale
Table 8- 18 Assignment of data record 20
Variable
Note
Type
L
Rw
Default
Min.
Max.
Register
Data record number Contains no. of data
record
USHORT 2 r 20 - - 3000
Length Data record length
information
USHORT 2 r 12 - - 3001
Application Information about which
application the data
record belongs to
USHORT 2 r 104 - - 3002
Version identifier Information about current
data record version
USHORT 2 r 1 1 255 3003
2000 Technology error
BIT
2
rw
1
-
-
3004.16
Reserve
BIT
0
rw
1
-
-
3004.15
2002 Trace error
BIT
0
rw
1
-
-
3004.14
2003 Zeroing aborted
BIT
0
rw
1
-
-
3004.13
3001 Totalizer error
BIT
0
rw
1
-
-
3004.12
2004 Trace memory full
BIT
0
rw
1
-
-
3004.11
3002 Calibration procedure
interrupted
BIT 0 rw 1 - - 3004.10
Reserve
BIT
0
rw
1
-
-
3004.9
Reserve
BIT
0
rw
1
-
-
3004.8
Reserve
BIT
0
rw
1
-
-
3004.7
Reserve
BIT
0
rw
1
-
-
3004.6
Reserve
BIT
0
rw
1
-
-
3004.5
Reserve
BIT
rw
1
-
-
3004.4
Reserve
BIT
rw
1
-
-
3004.3
Reserve BIT rw 1 - - 3004.2
Reserve
BIT
rw
1
-
-
3004.1
Reserve
USHORT
rw
-
-
3005.16