Scale parameters and functions of the belt scale
8.3 DR 3 Belt scale parameters
SIWAREX WP241
Manual, 04/2014, A5E33713528A
73
You can select any name, but it may not exceed 12 characters. You can enter any
designation.
Note
If the jumper is closed to protect data with verification capability, the parameter can no longer
be changed.
Trade scales requiring verification are subject to certain restrictions (available soon).
0 – no verification
1 – verification in accordance with OIML R50
2 – verification in accordance with NTEP Book 44
(approvals available soon).
Note
If the jumper is closed to protect data with verification capability, the parameter can no longer
be changed.
When setting parameters for the first time you must select between metric and imperial
systems.
The following units can be selected for the belt load:
0 – kg/m (metric)
1 – lbs/foot (imperial)
With the kg/m unit, the material flow rate can be specified in t/h or kg/h.
With the lbs/foot unit, the material flow rate can be specified in T/h, TL/h or lbs/h.
Note
If the jumper is closed to protect data with verification capability, the parameter can no longer
be changed.