Scale parameters and functions of the belt scale
8.3 DR 3 Belt scale parameters
SIWAREX WP241
72 Manual, 04/2014, A5E33713528A
Variable
Note
Type
L
Rw
Default
Min.
Max.
Register
Simulation mode
(Page 78)
Simulation (is enabled or disabled
via commands)
0: Simulation not permitted
1: Only weight simulation
permitted, weight is imported from
DR16 if simulation mode is enabled
2: Only speed simulation permitted,
speed is imported from DR16 if
simulation mode is enabled
3: Both permitted
Weight and speed are imported
from DR16 if simulation mode is
enabled
USHORT 2 rw 0 1048
Warm-up timer
(Page 78)
Status bit in DR30 "Warm-up time
running" remains TRUE for the
specified time (minutes)
USHORT 2 rw 30 1049
Interface for the legal
trade display
(Page 78)(available
soon)
0: HMI SecureDisplay at
ETHERNET
1: HMI SecureDisplay via S7
interface
USHORT 0 rw 0 1050
HMI SecureDisplay string header
version
UBYTE[2] 2 1051
Software version for
HMI SecureDisplay
with verification
capability
(Page 79)(available
soon)
HMI SecureDisplay version CHAR[12] 12 V1.05.02 1052
Minimum display size
in % of the HMI
SecureDisplay with
verification capability
(Page 79)
(available soon)
HMI SecureDisplay with verification
capability
USHORT 1058
Reserve
USHORT
1)
Parameter for calculation of calibration points

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP241 and is the answer not in the manual?

Siemens SIWAREX WP241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP241
CategoryAccessories
LanguageEnglish

Related product manuals