Scale parameters and functions of the belt scale
8.3 DR 3 Belt scale parameters
SIWAREX WP241
72 Manual, 04/2014, A5E33713528A
Simulation mode
(Page 78)
Simulation (is enabled or disabled
via commands)
0: Simulation not permitted
1: Only weight simulation
permitted, weight is imported from
DR16 if simulation mode is enabled
2: Only speed simulation permitted,
speed is imported from DR16 if
simulation mode is enabled
3: Both permitted
Weight and speed are imported
from DR16 if simulation mode is
USHORT 2 rw 0 1048
Warm-up timer
(Page 78)
Status bit in DR30 "Warm-up time
running" remains TRUE for the
USHORT 2 rw 30 1049
Interface for the legal
trade display
(Page 78)(available
soon)
0: HMI SecureDisplay at
ETHERNET
1: HMI SecureDisplay via S7
interface
USHORT 0 rw 0 1050
HMI SecureDisplay string header
UBYTE[2] 2 1051
Software version for
HMI SecureDisplay
with verification
capability
(Page 79)(available
HMI SecureDisplay version CHAR[12] 12 V1.05.02 1052
Minimum display size
in % of the HMI
SecureDisplay with
verification capability
(Page 79)
HMI SecureDisplay with verification
capability
USHORT 1058
1)
Parameter for calculation of calibration points