Scale parameters and functions of the belt scale
8.22 DR 30 Process state
SIWAREX WP241
124 Manual, 04/2014, A5E33713528A
2000 Group message "Technological error"
BIT 0 0 0 - - 3007.16
Current weight
FLOAT 4 r 0 - - 3008
Current belt load
Current belt load in weight unit per
FLOAT 4 r 0 - - 3010
Current belt load in %
Current belt load in % of nominal belt
FLOAT 4 r 0 - - 3012
Current flow rate
(Page 125)
Current material flow rate per hour FLOAT 4 r 0 - - 3014
Current flow rate in %
Current material flow rate in % of
FLOAT 4 r 0 - - 3016
Current speed
Current speed per second FLOAT 4 r 0 - - 3018
Current speed in %
Current speed in % of design speed FLOAT 4 r 0 - - 3020
Current master
totalizer (S1)
Current master totalizer (total operating
time)
DOUBLE 8 r 0 - - 3022
Current main totalizer
Current main totalizer FLOAT 4 r 0 - - 3026
Refresh counter for
process values
Refresh counter incremented by 1 if
weight values were changed