9.5 Message list
SIWAREX WP241
Manual, 04/2014, A5E33713528A
143
Data and operating errors
(code 5000 to 8999)
Error code
Description and remedy
6004 Command cannot be executed since
a dynamic procedure is not active
6004 Desired command cannot be executed since a dynamic
command is not currently being executed.
7000 Permitted number range violated 7000 The permitted number range, such as for weight values, was
violated.
7001 Regulation code not known 7001 Regulation code for application requiring official calibration
not known.
7002 Specifications of string lengths not
plausible
7002 The string header in a specified string variable is not
plausible.
7003 Specification of date / time not
plausible
7003 Specifications for date and time are not plausible.
7004 Assignment of DIs/DQs incorrect 7004 An error occurred while assigning the digital inputs or digital
outputs.
7006 Reserved
7006
Reserved
7007 The calibration weights or calibration
digits are not plausible
7007 Specifications for calibration weights or digits in data record
DR 3 are incorrect (minimum distance, reversal of incline).
7008 Zeroing parameters are not plausible 7008 The specifications for zeroing (data record DR 3) are not
plausible.
7010 Scale interval / rounding 7010 Scale interval or selection for rounding to decimal places is
not plausible.
7011 Filter parameters 7011 Specification of filter parameters is not plausible.
7013 Interface assignment for calibratable
HMI not plausible
7013 The assignment of the interface to the calibratable HMI is
incorrect.
7014 Specified time not plausible 7014 Specified time value is not plausible or may be signaled in
connection with additional errors
7016 Parameter assignment of analog
output not plausible
7016 The parameters for the analog output (data record DR 7) are
not plausible.
7017 MAC address cannot be changed
7017
7018 Error in IP mask
7018
The specified IP addresses (DR12) are not plausible.
7019 RS485 parameter error 7019 The specified RS485 interface parameters (DR13) are not
plausible.
7020 Speed parameter or sensor
parameter not plausible
7020 The speed parameter or sensor parameter in DR3 is not
plausible.
7021 Units are not plausible 7021 The selected units are not plausible (mixing of metric and
imperial parameters).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP241 and is the answer not in the manual?

Siemens SIWAREX WP241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP241
CategoryAccessories
LanguageEnglish

Related product manuals