Communication
11.1 Integration in SIMATIC S7-1200
SIWAREX WP241
158 Manual, 04/2014, A5E33713528A
A summary of all existing command codes can be found in chapter →Command lists
(Page 147).
The following equation for generation of a corresponding command code applies to the
reading of data records from the SIWAREX to the data block:
Command code = 2000 + X (X = desired data record number)
The following equation for generation of a corresponding command code applies to the
writing of data records from the data block to the SIWAREX:
Command code = 4000 + X (X = desired data record number)
Example
The following example clarifies the actions with command mailboxes and data records:
"Calibration weight" is to be set to a value of 60.5 by the CPU. Since "Calibration weight" is a
parameter of data record 3 (see chapter → Scale parameters and functions of the belt scale
(Page 69)), service mode must first be activated. This is possible using command code "1"
(see chapter → Command lists (Page 147)).
The variable "i_CMD_CODE" must therefore be assigned the value "1" and the associated
"bo_CMD_TRIGGER" set to TRUE. Subsequently, the module is directly in service mode
(DIAG LED flashes green):
i_CMD_CODE = 1
bo_CMD_TRIGGER = TRUE
Since only complete data records can be read or written, it is recommendable to now read
data record 3 into the CPU. This is carried out using command code 2003 (see chapter →
Command lists (Page 147)):
i_CMD_CODE = 2003
bo_CMD_TRIGGER = TRUE
All current data from data record 3 are now present in the data block. The calibration weight
is then set as desired to a value of 60.5:
CALIBRATION_WEIGHT = 60.5
The modified data record 3 must now be written into the SIWAREX again. This is carried out
using command code 4003 (see chapter → Command lists (Page 147)):
i_CMD_CODE = 4003
bo_CMD_TRIGGER = TRUE
The new calibration weight is now present in the SIWAREX and can be used. Service mode
for the module should subsequently be switched off again using command "2".
This procedure for reading and writing data records or parameters is identical for all data
records.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP241 and is the answer not in the manual?

Siemens SIWAREX WP241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP241
CategoryAccessories
LanguageEnglish

Related product manuals