Scale parameters and functions of the belt scale
8.8 DR 6 Limits
SIWAREX WP241
Manual, 04/2014, A5E33713528A
93
Variable
Note
Type
L
Rw
Default
Min.
Max.
Register
Maximum belt load
(Page 95)
Max. belt load for status display
'Maximum belt load violated' in %
of nominal belt load
FLOAT 4 rw 100 0 200 1288
Delay for belt load
limits (Page 95)
Delay for output of status display
for belt load (in ms)
LONG 4 rw 1 0 1290
Reserve
LONG
4
rw
1
0
1292
Medium load for
totalizing (Page 95)
Min. belt load required to start
totalizing. Specification in % of
nominal belt load
FLOAT
Reserve
4
rw
0
0
Frequency low pass
filter weight/belt
load/belt speed
(Page 96)
Low-pass filter - filtering of weight
limit frequency
0: filter switched off
Range fg: 0.05 … 50 Hz
FLOAT 4 rw 0.5 0 50 1298
Order no low pass
filter (Page 96)
Filter number 2*(1…5) USHORT 2 rw 4 1 5 1300
Reserve 2
Reserve
FLOAT
4
rw
0
0
1301
Frequency low pass
filter weight/belt
load/belt speed
(Page 96)
Low-pass filter - filtering of speed
limit frequency
0: filter switched off
fg: 0.05 … 50 Hz
FLOAT 4 rw 0 0 50 1302
Order no low pass
filter (Page 96)
Filter number 2*(1…5) SHORT 2 rw 4 1 5 1304
Reserve
FLOAT
4
rw
0
0
0
1305
Reserve
USHORT
2
rw
0
0
0
1307
Depth average filter
flow rate (Page 96)
Depth of average filter for weight
measurement (n x 10 ms)
USHORT 2 rw 0 0 0 1308

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP241 and is the answer not in the manual?

Siemens SIWAREX WP241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP241
CategoryAccessories
LanguageEnglish

Related product manuals