EasyManuals Logo

SKF KFGL User Manual

SKF KFGL
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
Page 86
EN
 Configure system monitoring
Step Key Display
1 Display flashes
(000 = factory setting)
Press for more than 2 s
2 Automatic display of first
parameter: "pause in timer operation"
Press briefly "PAUSE" LED flashes
(confirm code)
3 Beginning of monitoring settings
is displayed
Press until:
4 System monitoring switched off
(factory setting)
Press briefly
5
Press either until or
Monitoring via piston Monitoring via Pressure
detector "CS" LED flashes switch "PS" LED flashes
6
Press briefly Confirm new setting
7 New settings are written to memory,
Press for more than 2 s the values are activated and
the display clears
System monitoring can be changed to activate
or deactivate the monitoring functions for
lubrication.
When system monitoring is active, you can se-
lect monitoring via piston detector on progres-
sive systems or monitoring via pressure switch
on single-line systems.
11. KFGS programming
KFGS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF KFGL and is the answer not in the manual?

SKF KFGL Specifications

General IconGeneral
BrandSKF
ModelKFGL
CategoryWater Pump
LanguageEnglish

Related product manuals