49
Fig. 6.27
ADJUSTMENTS
6.5 ROW SPACING
Row spacing adjustments depend on the type of seed to be sown.
To adjust the row spacing, we need to operate on the frame. The following sections show the
adjustments to be performed in each frame model.
6.5.1 FIXED MACHINE
Row spacing in xed machines can
not be adjusted.
To change the distance between
metering units, the unit’s support
needs to be disassembled and re-
assembled at the desired position.
For this purpose, loosen the unit’s
securing screws, move the unit to
the desired position, and re-x it
by tightening the screws.
6.5.2 VARIANT MANUAL FIXED MACHINE
The machines VARIANT MANUAL FIXED allow an easy and quick adjustment to modify the dis-
tance between metering units.
The metering units are assembled along TWO SPINDLES, one for the machine’s left side units
and the other for those on the right side. In machines with an odd number of metering units,
the central unit is xed.
MOVE THE METERING UNITS ONLY WHEN THE MACHINE IS IN A RAISED POSITION.