5 Operation
Cold store application
Areas of application
Distinction is drawn between 4 different areas
of application, and between various different
modes of operation within these areas:
Area of
application
Cold store
equipment
Temperature
range up to
Operating time
Comment
1 Not required
-10°C Brief
Typical
application for
trucks that take
theloadfromthe
cooling truck into
thecoldstore,
where the load
is handled by
storage and
retrieval trucks.
2 Required
-30°C Continuous
Alternating
between indoor
and outdoor
use: time spent
outdoors long
enough for the
condensation to
drain off at least
(generally min.
30 minutes) or
short enough
so that no
condensation
can form
(generally max.
10 minutes).
Parking outside
ofthecoldarea.
3 Required
-30°C Continuous
Truck is parked
outside of the
cold store
area only for
maintenance
or repair work or
only for max. 10
minutes.
4 Required
-45°C Brief Cold store
equipment is
only designed for
continuous use
at temperatures
down to -30°C.
.
17