3 Safety
Safety regulations for handling co
nsumables
Measuring the battery’s insulation
resistance
NOTE
Nominal battery voltage < test voltage < 500
V.
Measure the insulation resistance with a
suitable measuring device.
The insulation resistance can be considered
sufficient if it measures at least 500
/V for the
nominal battery voltage against ground.
Contact the authorised service centre.
Measuring the insulation resistance of
the electrical system
NOTE
Nominal battery voltage < test voltage < 500
V.
Ensure that all volt
age sources have been
disconnected from t
he circuit to be tested.
Measure the insulation resistance with a
suitable measuring device.
The insulation resistance can be considered
sufficient if it measures at least 1000
/V for
the nominal battery voltage against ground.
Contact the author
ised service centre.
Safety regulati
ons for handling consumables
Permissible co
nsumables
DANGER
Failure to observe the safety regulations relating to
consumables may result in a risk of injury, death or
damage to the environment.
Observe the safety regulations when handling
these materials.
Refer to the maintenance data table for infor-
mation regarding the permissible substances
that are necessary for operation (refer to the
chapter entitled "Maintenance data table").
36
50988078001 [EN]