5 Operation
Handling the battery
CAUTION
Risk of component damage!
If you connect the battery male connector when
the truck is switched on (under load), an arc will be
produced. This can cause the contacts to erode,
which considerably shortens their service life.
– Do not connect the battery male connector when
the truck is switched on.
– Make sure that the truck is switched off before
connecting the battery male connector.
– Connect the battery male connector.
– Make sure that the battery cable cannot
become trapped when the reach carriage is
retracted with the battery.
– Unlock the emergency off switch.
– Switch on the truck.
– Press the foot switch.
– Retract the reach carriage with the battery
fully until the battery lock engages.
The lock must audibly engage. Push the
release lever down if necessary. If the battery
frame is locked incorrectly, traction is reduced
and the message A3405 is shown on the
display and operating unit. This status can
also be caused by the use of a non-standard
battery or by a technical fault.
If the battery is not included in the scope of
delivery of the truck, the battery lock must be
adjusted by the authorised service centre.
– Check or re-enter the battery data (battery
type and battery capacity) on the display
and operating unit; see the chapter entitled
"Setting the battery data".
21
0 50988078001 [EN]