Operating & Maintaining the Objet24 3D Printer
6–60
DOC-34014 Rev. C
11. Discardtheoldreflectorandlamp.
12. InsertthenewUVlamp/reflectorunitintothehousing.
13. MakesurethattheUV‐lampcableisinplace,insidethehousing,and
thentightenthesecuringscrews.
Figure 6-91: Cable position when installing the UV lamp
14. Replacethelampcover,andtightenthesecuringscrews.
15. ReplacetheUVlampassemblyintheprinter,makingsurethatthe
cablefitsintotheslottogetherwiththesidesecuringscrew.
Figure 6-92: UV-lamp cable after replacing the assembly
16. Tightenthetwosidesecuringscrews.
Dispose of the used UV lamp in accordance with environmental and safety
requirements.
WARNING: Broken lamp hazard.
UV lamps contain mercury. Deal with broken lamps with caution.
¾ Ventilate the room thoroughly.
¾ Use protective gloves when collecting mercury and lamp components.
¾ Remove spilled mercury with a method that prevents the generation of
mercury vapor, such as a syringe, packing tape or paper.
¾ Place the broken lamp, mercury and contaminated materials in an air-
tight, non-metallic container.