SummaCut cutter User’s Manual
Specifications 6-7
6.3.7
Environmental
(Cutter without media)
Operating Temperature
15 to 35° C
59 to 95° F
Storage temperature
-30 to 70° C
-22 to 158° F
Relative humidity
35 - 75 %, non-condensing
35 - 75 %, non-condensing
TABLE 9:
SUMMACUT ENVIRONMENTAL SPECIFICATIONS
IMPORTANT HINT: The use of dimensionally stable media is an essential
pre-
requisite to obtain high cut quality. Additionally, media expansion or
contraction may occur as a result of temperature variations. To improve
the dimensional stability of media, let it stabilize t
o the current
environmental conditions before use, for a minimum period of 24 hours.
6.3.8
Electrical
The power entry module detects the line voltage and switches automatically between
110V and 230V.
Main Supply: 48-62 Hz, single phase.
Nominal line
Min./Max. line
Fuse
110 V AC 88 - 132 V AC
T2.0A, 250V Schurter SPT
or equivalent.
230 V AC 176 - 264 V AC
T2.0A, 250V Schurter SPT
or equivalent.
TABLE 10:
SUMMACUT ELECTRICAL SPECIFICATIONS
Power requirements: 100-120 / 220-240 VAC, 50/60 Hz, 85 VA maximum
WARNING: For continued protection against risk of fire, replace only with
the same type and rating of fuse: T2.0A, 250V SCHURTER
SPT OR
EQUIVALENT.