12 DOSIMETER
The instrument operates as a Dosimeter in a very similar way to the Level Meter and, in addition to
SLM results, measures also basic dose parameters.
Below additional settings related with the Dosimeter function are described.
12.1 SELECTION OF THE DOSIMETER FUNCTION
To select the Dosimeter function, enter the Function
section, select the Meas. Funct position and press the
<Enter> key. In the Meas. Funct window, select the
Dosimeter function and press the <Enter> key.
<ENT>
12.2 SETTING GENERAL PARAMETERS GENERAL SETTINGS
Most general settings of the Dosimeter function are similar to the Level Meter
function (see chapter 5.1).
In addition, Dosimeter has a programmable five automatic pauses.
Programable automatic pauses
Automatic pause(s) can be switched off (Off) or can be programmed based on
absolute time (On).
If Pause is On, two additional positions appear which
enable setting time for pause start (Pause Begin) and
time for pause end (Pause End).
Note: In the Simple interface mode, the Pause parameters are hidden, but the instrument
will use settings previously defined in the Advanced mode or default settings (Off).
12.3 SETTING PROFILE PARAMETERS PROFILE X
Parameters of three profiles can be set in the Profile x
lists of parameters.
The following parameters can be programmed
independently for each profile: weighting filter (Filter),
peak filter (Filter Peak) and LEQ detector type
(Detector), criterion level (Crit. Level), threshold level
(Thr. Level), exchange rate (Exch. Rate), ULT Thresh.
and PTC Thresh..
<ENT>
Weighting filter selection
Z class 1 according to IEC 61672-1:2013 standard,
A class 1 according to IEC 651 and IEC 61672-1:2013 standards,
C class 1 according to IEC 651 and IEC 61672-1:2013 standards,
B class 1 according to IEC 651 standard.