EasyManua.ls Logo

Svantek SVAN 971 - Page 82

Svantek SVAN 971
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SVAN 971 User Manual
82
Start Synch.
Synchronization of the measurement/integration
start to the nearest full minute or hour of the
instrument real-time clock. It helps to measure in full
cycles.
Manual
5.1
Integration
Period
Time of measurement/integration or averaging of
the Summary Results: from 1 second to Infinitive.
For example, with 8 hours integration period the
LEQ result will be averaged for 8 hours. In case of
Infinitive, the measurement will last until the user
presses the <Stop> key.
Manual
5.1
Repetition
Cycles
Number of measurement/integration repetitions
after the <Start> key pressure.
This enables to make a series of measurements
without pressing the <Start> key and save this
series in the results file.
Manual
5.1
LEQ
Integration
Type of integration of RMS based results (RMS
detector): Linear or Exponential. The IEC 61672-
1:2013 standard requires Linear integration, without
time weighting, however in number of countries old
regulation refers to the Exponential RMS integration
with standard time weighting: Fast or Slow.
Manual
5.1
Linear
Linear type of integration of RMS based results
(RMS detector), without time weighting according to
the IEC 61672-1:2013 standard.
Manual
5.1
Exponential
Exponential type of integration of RMS based
results (RMS detector), where averaging is a
continuous averaging process that weighs current
and past data differently. The amount of weight
given to past data as compared to current data
depends on the exponential time constant. In
exponential averaging, the averaging process
continues indefinitely.
Manual
5.1
Day Time
Limits
Definition of the day and night periods required by
the local standards: 618h and 719h. These limits
are used for the calculation of the L(den) function.
Manual
5.1

Table of Contents