Chapter 4 TL1 Reference
Commands
118 TimeSource User’s Guide 097-72020-01 Revision K – December 2005
OPT-a
(Additional
E1 outputs
on
990-72020-0
2 systems
only)
ALMOUT=b b = AIS Output is AIS during alarm
b =
SQUELCH
Output is squelched during alarm
b = SSM Outputs are at “SSUT” quality level during
holdover alarm (SSM requires CAS4 or
CCS4 output framing)
FRAMING=b b=CAS Output framing is CAS
b=CAS4 Output framing is CAS4
b=CCS Output framing is CCS
b=CCS4 Output framing is CCS4
b=NONE Output framing is NONE (analog) (If
ALMOUT is SQUELCH, then signal turns off
during Holdover alarm. Any other ALMOUT
option does not affect output during alarm)
OPT-a
(990-72020-0
4 systems
only)
ALMOUT=b b = AIS When the ESCIU detects an LOS on an
input span, AIS is output to the NE (the E1
option does not affect output during alarm)
b =
PASSTHRU
When the ESCIU detects an LOS on an
input span, the E1 alignment sequence is
passed through to the NE with the original
input alarm