097-72020-01 Revision K – December 2005 TimeSource User’s Guide 117
Chapter 4 TL1 Reference
Commands
SPAN-a ENSEMBLER=b
(See Notes 7, 8)
b = ALW Span is ensembled
b = INH Span is not ensembled
SSM=b (See Note
8)
b = ALW SSM qualifies span input
b = INH SSM does not qualify span input
SSMCHANNEL=b b = 4 Uses Sa4 bit
b = 5 Uses Sa5 bit
b = 6 Uses Sa6 bit
b = 7 Uses Sa7 bit
b = 8 Uses Sa8 bit
E1-a ALMOUT=b b = AIS Output is AIS during alarm
b =
SQUELCH
Output is squelched during alarm
b = SSM Outputs are at “SSUT” quality level during
holdover alarm (SSM requires CAS4 or
CCS4 output framing)
FRAMING=b b=CAS Output framing is CAS
b=CAS4 Output framing is CAS4
b=CCS Output framing is CCS
b=CCS4 Output framing is CCS4
b=NONE Output framing is NONE (analog) (If
ALMOUT is SQUELCH, then signal turns off
during Holdover alarm. Any other ALMOUT
option does not affect output during alarm)