Chapter 4 TL1 Reference
Commands
116 TimeSource User’s Guide 097-72020-01 Revision K – December 2005
TS3100,
SPAN A&B,
RO A&B
TIME=x x = HH-MM Hour (00-999) and minute (00-59) time to
escalate alarm
x = 0 No alarm escalation
SEVERITY1=x
(See Note 4)
x = CR Severity of initial alarm prior to escalation
x = MJ
x = MN
x = EV
x = NA
TS3100,
SPAN A&B,
RO A&B
(cont’d)
SEVERITY2=x
(See Note 4)
x = CR Severity of ESCALATED alarm
x = MJ
x = MN
x = EV
x = NA
SERAFF1=x
(See Note 4)
x = SA Service affecting state of initial alarm prior to
escalation
x = NSA
SERAFF2=x
(See Note 4)
x = SA Service affecting state of escalated alarm
x = NSA
TS3100 NTPPWD=x
(See Note 5)
x = 6 ASCII
characters
NTP Password (contact factory)
GPS ANTCBLDLY=a a=0 to 330 Antenna cable length (meters)
ANTELEVMASK=a a=0 to 45 Antenna elevation mask angle (degrees)
RO-a ENSEMBLER=b
(See Note 6)
b = ALW Remote oscillator is ensembled
b = INH Remote oscillator is not ensembled