097-72020-01 Revision K – December 2005 TimeSource User’s Guide 139
Chapter 4 TL1 Reference
Commands
TS3100
(cont’d)
IPNTP=a a=ALW NTP feature activated
DCDPASSTHRU INH DCD port communication is inhibited
ALW1 COM1 is the DCD interface port
ALW2 COM2 is the DCD interface port
DCCUSERPORT=a
(See Note 1)
a=1 COM1
a=2 COM2
a=3, 5001,
5002, 5003,
5004
COM3 or IP port 5001 to 5004
GPS ANTCBLDLY=a a = 0 to 330 Antenna cable length (meters)
ANTELEVMASK=a a = 0 to 45 Antenna elevation mask angle (degrees)
RO-a ENSEMBLER=b b = ALW Remote oscillator is ensembled
b = INH Remote oscillator is not ensembled
MONITOR=b b = ALW Remote oscillator is monitored
b = INH Remote oscillator is not monitored
SPAN-a ENSEMBLER=b a = ALW E1 span is ensembled
a = INH E1 span is not ensembled
MONITOR=b a = ALW E1 span is monitored
a = INH E1 span is not monitored
SSM=b a = ALW SSM message is used to qualify port
a = INH SSM message is not used to qualify port
SIGNAL=b b=ANALOG Span input signal is 2.048 MHz
b=DIGITAL Span input signal is 2.048 Mb/s
SSMCHANNEL=b b=4 Uses Sa4 bit
b=5 Uses Sa5 bit
b=6 Uses Sa6 bit
b=7 Uses Sa7 bit
b=8 Uses Sa8 bit