E1-a FRAMING=b b=CAS Output framing is CAS
b=CAS4 Output framing is CAS4
b=CCS Output framing is CCS
b=CCS4 Output framing is CCS4
b=NONE Output framing is NONE (if an analog
signal). (If ALMOUT is SQUELCH, the
signal will turn off during holdover alarm.
No other ALMOUT option affects output
during alarm.)
ALMOUT=b b = AIS Output during holdover alarm is AIS
b = SQUELCH No output during holdover alarm
b = SSM Output is “SSUT” quality level message
during holdover alarm (SSM requires
output framing of CAS4 or CCS4)
OPT-a
(Additional
eight E1
outputs for
990-72020-
02 systems
only)
ALMOUT=b b = AIS Output during holdover alarm is AIS
b = SQUELCH No output during holdover alarm
b = SSM Outputs is “SSUT” quality level message
during holdover alarm (SSM requires
CAS4 or CCS4 output framing)
FRAMING=b b = CAS Output framing is CAS
b = CAS4 Output framing is CAS4
b = CCS Output framing is CCS
b = CCS4 Output framing is CCS4
b = NONE Output framing is NONE (if an analog
signal) (If ALMOUT is SQUELCH, the
signal turns off during holdover alarm. No
other ALMOUT option affects output
during alarm.)